An Incorrect Behavior Order vulnerability in the MAP-E automatic tunneling mechanism of Juniper Networks Junos OS allows an attacker to send certain malformed IPv4 or IPv6 packets to cause a Denial of Service (DoS) to the PFE on the device which is disabled as a result of the processing of these packets. Continued receipt and processing of these malformed IPv4 or IPv6 packets will create a sustained Denial of Service (DoS) condition. This issue only affects MPC 7/8/9/10/11 cards, when MAP-E IP reassembly is enabled on these cards. An indicator of compromise is the output: FPC [“FPC ID” # e.g. “0”] PFE #{PFE ID # e.g. “1”] : Fabric Disabled Example: FPC 0 PFE #1 : Fabric Disabled when using the command: show chassis fabric fpcs An example of a healthy result of the command use would be: user@device-re1> show chassis fabric fpcs Fabric management FPC state: FPC 0 PFE #0 Plane 0: Plane enabled Plane 1: Plane enabled Plane 2: Plane enabled Plane 3: Plane enabled Plane 4: Plane enabled Plane 5: Plane enabled Plane 6: Plane enabled Plane 7: Plane enabled This issue affects: Juniper Networks Junos OS on MX Series with MPC 7/8/9/10/11 cards, when MAP-E IP reassembly is enabled on these cards. 17.2 version 17.2R1 and later versions; 17.3 versions prior to 17.3R3-S9; 17.4 versions prior to 17.4R2-S12, 17.4R3-S3; 18.1 versions prior to 18.1R3-S11; 18.2 versions prior to 18.2R2-S6, 18.2R3-S3; 18.3 versions prior to 18.3R2-S4, 18.3R3-S1; 18.4 versions prior to 18.4R1-S8, 18.4R2-S5, 18.4R3; 19.1 versions prior to 19.1R1-S6, 19.1R2-S2, 19.1R3; 19.2 versions prior to 19.2R1-S5, 19.2R2; 19.3 versions prior to 19.3R2-S5, 19.3R3. This issue does not affect Juniper Networks Junos OS versions prior to 17.2R1.
NVD-CWE-Other
CVE-2021-31386
A Protection Mechanism Failure vulnerability in the J-Web HTTP service of Juniper Networks Junos OS allows a remote unauthenticated attacker to perform Person-in-the-Middle (PitM) attacks against the device. This issue affects: Juniper Networks Junos OS 12.3 versions prior to 12.3R12-S20; 15.1 versions prior to 15.1R7-S11; 18.3 versions prior to 18.3R3-S6; 18.4 versions prior to 18.4R3-S10; 19.1 versions prior to 19.1R3-S7; 19.2 versions prior to 19.2R3-S4; 19.3 versions prior to 19.3R3-S4; 19.4 versions prior to 19.4R3-S6; 20.1 versions prior to 20.1R3-S2; 20.2 versions prior to 20.2R3-S3; 20.3 versions prior to 20.3R3-S1; 20.4 versions prior to 20.4R3; 21.1 versions prior to 21.1R3; 21.2 versions prior to 21.2R2.
CVE-2021-31411
Insecure temporary directory usage in frontend build functionality of com.vaadin:flow-server versions 2.0.9 through 2.5.2 (Vaadin 14.0.3 through Vaadin 14.5.2), 3.0 prior to 6.0 (Vaadin 15 prior to 19), and 6.0.0 through 6.0.5 (Vaadin 19.0.0 through 19.0.4) allows local users to inject malicious code into frontend resources during application rebuilds.
CVE-2021-3130
Within the Open-AudIT up to version 3.5.3 application, the web interface hides SSH secrets, Windows passwords, and SNMP strings from users using HTML ‘password field’ obfuscation. By using Developer tools or similar, it is possible to change the obfuscation so that the credentials are visible.
CVE-2021-31338
A vulnerability has been identified in SINEMA Remote Connect Client (All versions < V3.0 SP1). Affected devices allow to modify configuration settings over an unauthenticated channel. This could allow a local attacker to escalate privileges and execute own code on the device.
CVE-2021-31249
A CRLF injection vulnerability was found on BF-430, BF-431, and BF-450M TCP/IP Converter devices from CHIYU Technology Inc due to a lack of validation on the parameter redirect= available on multiple CGI components.