Improper access control vulnerability in GROWI versions v4.2.2 and earlier allows a remote unauthenticated attacker to read the user’s personal information and/or server’s internal information via unspecified vectors.
NVD-CWE-Other
CVE-2021-20694
Improper access control vulnerability in DAP-1880AC firmware version 1.21 and earlier allows a remote authenticated attacker to bypass access restriction and to start a telnet service via unspecified vectors.
CVE-2021-20584
IBM Sterling File Gateway 2.2.0.0 through 6.1.1.0 could allow a remote attacker to upload arbitrary files, caused by improper access controls. IBM X-Force ID: 199397.
CVE-2021-20608
Improper Handling of Length Parameter Inconsistency vulnerability in Mitsubishi Electric GX Works2 versions 1.606G and prior allows a remote unauthenticated attacker to cause a DoS condition in GX Works2 by getting GX Works2 to read a tampered program file from a Mitsubishi Electric PLC by sending malicious crafted packets to tamper with the program file.
CVE-2021-20610
Improper Handling of Length Parameter Inconsistency vulnerability in Mitsubishi Electric MELSEC iQ-R Series R00/01/02CPU Firmware versions “24” and prior, Mitsubishi Electric MELSEC iQ-R Series R04/08/16/32/120(EN)CPU Firmware versions “57” and prior, Mitsubishi Electric MELSEC iQ-R Series R08/16/32/120SFCPU Firmware versions “28” and prior, Mitsubishi Electric MELSEC iQ-R Series R08/16/32/120PCPU Firmware versions “29” and prior, Mitsubishi Electric MELSEC iQ-R Series R08/16/32/120PSFCPU Firmware versions “08” and prior, Mitsubishi Electric MELSEC iQ-R Series R16/32/64MTCPU Operating system software version “23” and prior, Mitsubishi Electric MELSEC iQ-R Series R12CCPU-V Firmware versions “16” and prior, Mitsubishi Electric MELSEC Q Series Q03UDECPU The first 5 digits of serial No. “23121” and prior, Mitsubishi Electric MELSEC Q Series Q04/06/10/13/20/26/50/100UDEHCPU The first 5 digits of serial No. “23121” and prior, Mitsubishi Electric MELSEC Q Series Q03/04/06/13/26UDVCPU The first 5 digits of serial No. “23071” and prior, Mitsubishi Electric MELSEC Q Series Q04/06/13/26UDPVCPU The first 5 digits of serial No. “23071” and prior, Mitsubishi Electric MELSEC Q Series Q12DCCPU-V The first 5 digits of serial No. “24031” and prior, Mitsubishi Electric MELSEC Q Series Q24DHCCPU-V(G) The first 5 digits of serial No. “24031” and prior, Mitsubishi Electric MELSEC Q Series Q24/26DHCCPU-LS The first 5 digits of serial No. “24031” and prior, Mitsubishi Electric MELSEC Q Series MR-MQ100 Operating system software version “F” and prior, Mitsubishi Electric MELSEC Q Series Q172/173DCPU-S1 Operating system software version “W” and prior, Mitsubishi Electric MELSEC Q Series Q172/173DSCPU All versions, Mitsubishi Electric MELSEC Q Series Q170MCPU Operating system software version “W” and prior, Mitsubishi Electric MELSEC Q Series Q170MSCPU(-S1) All versions, Mitsubishi Electric MELSEC L Series L02/06/26CPU(-P) The first 5 digits of serial No. “23121” and prior, Mitsubishi Electric MELSEC L Series L26CPU-(P)BT The first 5 digits of serial No. “23121” and prior and Mitsubishi Electric MELIPC Series MI5122-VW Firmware versions “05” and prior allows a remote unauthenticated attacker to cause a denial-of-service (DoS) condition by sending specially crafted packets. System reset is required for recovery.
CVE-2021-20617
Improper access control vulnerability in acmailer ver. 4.0.1 and earlier, and acmailer DB ver. 1.1.3 and earlier allows remote attackers to execute an arbitrary OS command, or gain an administrative privilege which may result in obtaining the sensitive information on the server via unspecified vectors.