api/views/user.py in LibrePhotos before e19e539 has incorrect access control.
NVD-CWE-Other
CVE-2023-22405
An Improper Preservation of Consistency Between Independent Representations of Shared State vulnerability in the Packet Forwarding Engine (PFE) of Juniper Networks Junos OS allows an adjacent, unauthenticated attacker to cause a Denial of Service (DoS) to device due to out of resources. When a device is configured with “service-provider/SP style” switching, and mac-limiting is configured on an Aggregated Ethernet (ae) interface, and then a PFE is restarted or the device is rebooted, mac-limiting doesn’t work anymore. Please note that the issue might not be apparent as traffic will continue to flow through the device although the mac table and respective logs will indicate that mac limit is reached. Functionality can be restored by removing and re-adding the MAC limit configuration. This issue affects Juniper Networks Junos OS on QFX5k Series, EX46xx Series: All versions prior to 20.2R3-S5; 20.3 versions prior to 20.3R3-S5; 20.4 versions prior to 20.4R3-S4; 21.1 versions prior to 21.1R3-S3; 21.2 versions prior to 21.2R3-S1; 21.3 versions prior to 21.3R3 on; 21.4 versions prior to 21.4R3 on; 22.1 versions prior to 22.1R2 on.
CVE-2023-22413
An Improper Check or Handling of Exceptional Conditions vulnerability in the IPsec library of Juniper Networks Junos OS allows a network-based, unauthenticated attacker to cause Denial of Service (DoS). On all MX platforms with MS-MPC or MS-MIC card, when specific IPv4 packets are processed by an IPsec6 tunnel, the Multiservices PIC Management Daemon (mspmand) process will core and restart. This will lead to FPC crash. Traffic flow is impacted while mspmand restarts. Continued receipt of these specific packets will cause a sustained Denial of Service (DoS) condition. This issue only occurs if an IPv4 address is not configured on the multiservice interface. This issue affects: Juniper Networks Junos OS on MX Series All versions prior to 19.4R3-S9; 20.1 version 20.1R3-S5 and later versions; 20.2 versions prior to 20.2R3-S5; 20.3 versions prior to 20.3R3-S5; 20.4 versions prior to 20.4R3-S4; 21.1 versions prior to 21.1R3-S3; 21.2 versions prior to 21.2R3-S1; 21.3 versions prior to 21.3R3; 21.4 versions prior to 21.4R2-S1, 21.4R3; 22.1 versions prior to 22.1R2.
CVE-2023-22477
Mercurius is a GraphQL adapter for Fastify. Any users of Mercurius until version 10.5.0 are subjected to a denial of service attack by sending a malformed packet over WebSocket to `/graphql`. This issue was patched in #940. As a workaround, users can disable subscriptions.
CVE-2023-22600
InHand Networks InRouter 302, prior to version IR302 V3.5.56, and InRouter 615, prior to version InRouter6XX-S-V2.3.0.r5542, contain vulnerability CWE-284: Improper Access Control. They allow unauthenticated devices to subscribe to MQTT topics on the same network as the device manager. An unauthorized user who knows of an existing topic name could send and receive messages to and from that topic. This includes the ability to send GET/SET configuration commands, reboot commands, and push firmware updates.
CVE-2023-22610
A CWE-285: Improper Authorization vulnerability exists that could cause Denial of Service against the Geo SCADA server when specific messages are sent to the server over the database server TCP port. Affected Products: EcoStruxure Geo SCADA Expert 2019 – 2021 (formerly known as ClearSCADA) (Versions prior to October 2022)