CVE-2021-27414

February 23, 2023 by

An attacker could trick a user of Hitachi ABB Power Grids Ellipse Enterprise Asset Management (EAM) versions prior to and including 9.0.25 into visiting a malicious website posing as a login page for the Ellipse application and gather authentication credentials.

CVE-2021-27413

February 23, 2023 by

Omron CX-One Versions 4.60 and prior, including CX-Server Versions 5.0.29.0 and prior, are vulnerable to a stack-based buffer overflow, which may allow an attacker to execute arbitrary code.

CVE-2021-27412

February 23, 2023 by

Delta Electronics DOPSoft Versions 4.0.10.17 and prior are vulnerable to an out-of-bounds read, which may allow an attacker to execute arbitrary code.

CVE-2021-27411

February 23, 2023 by

Micrium OS Versions 5.10.1 and prior are vulnerable to integer wrap-around in functions Mem_DynPoolCreate, Mem_DynPoolCreateHW and Mem_PoolCreate. This unverified memory assignment can lead to arbitrary memory allocation, resulting in unexpected behavior such as very small blocks of memory being allocated instead of very large ones.

CVE-2021-27410

February 23, 2023 by

The affected product is vulnerable to an out-of-bounds write, which may result in corruption of data or code execution on the Welch Allyn medical device management tools (Welch Allyn Service Tool: versions prior to v1.10, Welch Allyn Connex Device Integration Suite – Network Connectivity Engine (NCE): versions prior to v5.3, Welch Allyn Software Development Kit (SDK): versions prior to v3.2, Welch Allyn Connex Central Station (CS): versions prior to v1.8.6, Welch Allyn Service Monitor: versions prior to v1.7.0.0, Welch Allyn Connex Vital Signs Monitor (CVSM): versions prior to v2.43.02, Welch Allyn Connex Integrated Wall System (CIWS): versions prior to v2.43.02, Welch Allyn Connex Spot Monitor (CSM): versions prior to v1.52, Welch Allyn Spot Vital Signs 4400 Device (Spot 4400) / Welch Allyn Spot 4400 Vital Signs Extended Care Device: versions prior to v1.11.00).

CVE-2021-27408

February 23, 2023 by

The affected product is vulnerable to an out-of-bounds read, which can cause information leakage leading to arbitrary code execution if chained to the out-of-bounds write vulnerability on the Welch Allyn medical device management tools (Welch Allyn Service Tool: versions prior to v1.10, Welch Allyn Connex Device Integration Suite – Network Connectivity Engine (NCE): versions prior to v5.3, Welch Allyn Software Development Kit (SDK): versions prior to v3.2, Welch Allyn Connex Central Station (CS): versions prior to v1.8.6, Welch Allyn Service Monitor: versions prior to v1.7.0.0, Welch Allyn Connex Vital Signs Monitor (CVSM): versions prior to v2.43.02, Welch Allyn Connex Integrated Wall System (CIWS): versions prior to v2.43.02, Welch Allyn Connex Spot Monitor (CSM): versions prior to v1.52, Welch Allyn Spot Vital Signs 4400 Device (Spot 4400) / Welch Allyn Spot 4400 Vital Signs Extended Care Device: versions prior to v1.11.00).

  • « Go to Previous Page
  • Go to page 1
  • Interim pages omitted …
  • Go to page 13510
  • Go to page 13511
  • Go to page 13512
  • Go to page 13513
  • Go to page 13514
  • Interim pages omitted …
  • Go to page 18763
  • Go to Next Page »

Copyright CVE Vulnerabilities 2023
Data Sources:

  • NIST
  • MITRE
  • CVE Search
  • Open CVE