P2M pool freeing may take excessively long The P2M pool backing second level address translation for guests may be of significant size. Therefore its freeing may take more time than is reasonable without intermediate preemption checks. Such checking for the need to preempt was so far missing.
CVE-2022-33745
insufficient TLB flush for x86 PV guests in shadow mode For migration as well as to work around kernels unaware of L1TF (see XSA-273), PV guests may be run in shadow paging mode. To address XSA-401, code was moved inside a function in Xen. This code movement missed a variable changing meaning / value between old and new code positions. The now wrong use of the variable did lead to a wrong TLB flush condition, omitting flushes where such are necessary.
CVE-2022-33744
Arm guests can cause Dom0 DoS via PV devices When mapping pages of guests on Arm, dom0 is using an rbtree to keep track of the foreign mappings. Updating of that rbtree is not always done completely with the related lock held, resulting in a small race window, which can be used by unprivileged guests via PV devices to cause inconsistencies of the rbtree. These inconsistencies can lead to Denial of Service (DoS) of dom0, e.g. by causing crashes or the inability to perform further mappings of other guests’ memory pages.
CVE-2022-33743
network backend may cause Linux netfront to use freed SKBs While adding logic to support XDP (eXpress Data Path), a code label was moved in a way allowing for SKBs having references (pointers) retained for further processing to nevertheless be freed.
CVE-2022-33742
Linux disk/nic frontends data leaks T[his CNA information record relates to multiple CVEs; the text explains which aspects/vulnerabilities correspond to which CVE.] Linux Block and Network PV device frontends don’t zero memory regions before sharing them with the backend (CVE-2022-26365, CVE-2022-33740). Additionally the granularity of the grant table doesn’t allow sharing less than a 4K page, leading to unrelated data residing in the same 4K page as data shared with a backend being accessible by such backend (CVE-2022-33741, CVE-2022-33742).
CVE-2022-33741
Linux disk/nic frontends data leaks T[his CNA information record relates to multiple CVEs; the text explains which aspects/vulnerabilities correspond to which CVE.] Linux Block and Network PV device frontends don’t zero memory regions before sharing them with the backend (CVE-2022-26365, CVE-2022-33740). Additionally the granularity of the grant table doesn’t allow sharing less than a 4K page, leading to unrelated data residing in the same 4K page as data shared with a backend being accessible by such backend (CVE-2022-33741, CVE-2022-33742).