A CWE-294: Authentication Bypass by Capture-replay vulnerability exists that could cause an unauthenticated connection to the UPS when a malformed connection is sent. Affected Product: SmartConnect Family: SMT Series (SMT Series ID=1015: UPS 04.5 and prior), SMC Series (SMC Series ID=1018: UPS 04.2 and prior), SMTL Series (SMTL Series ID=1026: UPS 02.9 and prior), SCL Series (SCL Series ID=1029: UPS 02.5 and prior / SCL Series ID=1030: UPS 02.5 and prior / SCL Series ID=1036: UPS 02.5 and prior / SCL Series ID=1037: UPS 03.1 and prior), SMX Series (SMX Series ID=1031: UPS 03.1 and prior)
CVE-2022-22805
A CWE-120: Buffer Copy without Checking Size of Input (‘Classic Buffer Overflow’) vulnerability exists that could cause remote code execution when an improperly handled TLS packet is reassembled. Affected Product: SmartConnect Family: SMT Series (SMT Series ID=1015: UPS 04.5 and prior), SMC Series (SMC Series ID=1018: UPS 04.2 and prior), SMTL Series (SMTL Series ID=1026: UPS 02.9 and prior), SCL Series (SCL Series ID=1029: UPS 02.5 and prior / SCL Series ID=1030: UPS 02.5 and prior / SCL Series ID=1036: UPS 02.5 and prior / SCL Series ID=1037: UPS 03.1 and prior), SMX Series (SMX Series ID=1031: UPS 03.1 and prior)
CVE-2022-22804
A CWE-79: Improper Neutralization of Input During Web Page Generation (‘Cross-site Scripting’) vulnerability exists that could allow an authenticated attacker to view data, change settings, or impact availability of the software when the user visits a page containing the injected payload. Affected Product: EcoStruxure Power Monitoring Expert (Versions 2020 and prior)
CVE-2022-2280
Cross-site Scripting (XSS) – Stored in GitHub repository microweber/microweber prior to 1.2.19.
CVE-2022-22798
Sysaid – Pro Plus Edition, SysAid Help Desk Broken Access Control v20.4.74 b10, v22.1.20 b62, v22.1.30 b49 – An attacker needs to log in as a guest after that the system redirects him to the service portal or EndUserPortal.JSP, then he needs to change the path in the URL to /ConcurrentLogin%2ejsp after that he will receive an error message with a login button, by clicking on it, he will connect to the system dashboard. The attacker can receive sensitive data like server details, usernames, workstations, etc. He can also perform actions such as uploading files, deleting calls from the system.
CVE-2022-22797
Sysaid – sysaid Open Redirect – An Attacker can change the redirect link at the parameter “redirectURL” from”GET” request from the url location: /CommunitySSORedirect.jsp?redirectURL=https://google.com. Unvalidated redirects and forwards are possible when a web application accepts untrusted input that could cause the web application to redirect the request to a URL contained within untrusted input. By modifying untrusted URL input to a malicious site, an attacker may successfully launch a phishing scam and steal user credentials.
