The Download Monitor WordPress plugin before 4.5.91 does not ensure that files to be downloaded are inside the blog folders, and not sensitive, allowing high privilege users such as admin to download the wp-config.php or /etc/passwd even in an hardened environment or multisite setup.
CVE-2022-22219
Due to the Improper Handling of an Unexpected Data Type in the processing of EVPN routes on Juniper Networks Junos OS and Junos OS Evolved, an attacker in direct control of a BGP client connected to a route reflector, or via a machine in the middle (MITM) attack, can send a specific EVPN route contained within a BGP Update, triggering a routing protocol daemon (RPD) crash, leading to a Denial of Service (DoS) condition. Continued receipt and processing of these specific EVPN routes could create a sustained Denial of Service (DoS) condition. This issue only occurs on BGP route reflectors, only within a BGP EVPN multicast environment, and only when one or more BGP clients have ‘leave-sync-route-oldstyle’ enabled. This issue affects: Juniper Networks Junos OS 21.3 versions prior to 21.3R3-S2; 21.4 versions prior to 21.4R2-S2, 21.4R3; 22.1 versions prior to 22.1R1-S2, 22.1R3; 22.2 versions prior to 22.2R2. Juniper Networks Junos OS Evolved 21.3 version 21.3R1-EVO and later versions prior to 21.4R3-EVO; 22.1 versions prior to 22.1R1-S2-EVO, 22.1R3-EVO; 22.2 versions prior to 22.2R2-EVO. This issue does not affect: Juniper Networks Junos OS versions prior to 21.3R1. Juniper Networks Junos OS Evolved versions prior to 21.3R1-EVO.
CVE-2022-22218
On SRX Series devices, an Improper Check for Unusual or Exceptional Conditions when using Certificate Management Protocol Version 2 (CMPv2) auto re-enrollment, allows a network-based, unauthenticated attacker to cause a Denial of Service (DoS) by crashing the pkid process. The pkid process cannot handle an unexpected response from the Certificate Authority (CA) server, leading to crash. A restart is required to restore services. This issue affects: Juniper Networks Junos OS on SRX Series: All versions prior to 19.1R3-S9; 19.2 versions prior to 19.2R3-S6; 19.3 versions prior to 19.3R3-S7; 19.4 versions prior to 19.4R3-S9; 20.2 versions prior to 20.2R3-S5; 20.3 versions prior to 20.3R3-S4; 20.4 versions prior to 20.4R3-S4; 21.1 versions prior to 21.1R3-S1; 21.2 versions prior to 21.2R3; 21.3 versions prior to 21.3R2; 21.4 versions prior to 21.4R2.
CVE-2022-22217
An Improper Check for Unusual or Exceptional Conditions vulnerability in the Packet Forwarding Engine (PFE) of Juniper Networks Junos OS allows an adjacent unauthenticated attacker to cause a Denial of Service (DoS). The issue is caused by malformed MLD packets looping on a multi-homed Ethernet Segment Identifier (ESI) when VXLAN is configured. These MLD packets received on a multi-homed ESI are sent to the peer, and then incorrectly forwarded out the same ESI, violating the split horizon rule. This issue only affects QFX10K Series switches, including the QFX10002, QFX10008, and QFX10016. Other products and platforms are unaffected by this vulnerability. This issue affects Juniper Networks Junos OS on QFX10K Series: All versions prior to 19.1R3-S9; 19.2 versions prior to 19.2R1-S9, 19.2R3-S5; 19.3 versions prior to 19.3R3-S6; 19.4 versions prior to 19.4R2-S7, 19.4R3-S8; 20.1 versions prior to 20.1R3-S4; 20.2 versions prior to 20.2R3-S4; 20.3 versions prior to 20.3R3-S2; 20.4 versions prior to 20.4R3-S2; 21.1 versions prior to 21.1R3; 21.2 versions prior to 21.2R2-S1, 21.2R3; 21.3 versions prior to 21.3R2.
CVE-2022-22216
An Exposure of Sensitive Information to an Unauthorized Actor vulnerability in the PFE of Juniper Networks Junos OS on PTX Series and QFX10k Series allows an adjacent unauthenticated attacker to gain access to sensitive information. PTX1000 and PTX10000 Series, and QFX10000 Series and PTX5000 Series devices sometimes do not reliably pad Ethernet packets, and thus some packets can contain fragments of system memory or data from previous packets. This issue is also known as ‘Etherleak’ and often detected as CVE-2003-0001. This issue affects: Juniper Networks Junos OS on PTX1000 and PTX10000 Series: All versions prior to 18.4R3-S11; 19.1 versions prior to 19.1R2-S3, 19.1R3-S7; 19.2 versions prior to 19.2R1-S8, 19.2R3-S4; 19.3 versions prior to 19.3R3-S4; 19.4 versions prior to 19.4R2-S5, 19.4R3-S6; 20.1 versions prior to 20.1R3-S2; 20.2 versions prior to 20.2R3-S3; 20.3 versions prior to 20.3R3-S2; 20.4 versions prior to 20.4R3-S4; 21.1 versions prior to 21.1R2-S1, 21.1R3; 21.2 versions prior to 21.2R1-S1, 21.2R2. Juniper Networks Junos OS on QFX10000 Series and PTX5000 Series: All versions prior to 18.3R3-S6; 18.4 versions prior to 18.4R2-S9, 18.4R3-S10; 19.1 versions prior to 19.1R2-S3, 19.1R3-S7; 19.2 versions prior to 19.2R1-S8, 19.2R3-S4; 19.3 versions prior to 19.3R3-S4; 19.4 versions prior to 19.4R2-S6, 19.4R3-S6; 20.1 versions prior to 20.1R3-S2; 20.2 versions prior to 20.2R3-S3; 20.3 versions prior to 20.3R3-S1; 20.4 versions prior to 20.4R3-S1; 21.1 versions prior to 21.1R2-S1, 21.1R3; 21.2 versions prior to 21.2R2.
CVE-2022-22215
A Missing Release of File Descriptor or Handle after Effective Lifetime vulnerability in plugable authentication module (PAM) of Juniper Networks Junos OS and Junos OS Evolved allows a locally authenticated attacker with low privileges to cause a Denial of Service (DoS). It is possible that after the termination of a gRPC connection the respective/var/run/.env file is not getting deleted which if occurring repeatedly can cause inode exhaustion. Inode exhaustion can present itself in two different ways: 1. The following log message can be observed: host kernel: pid (), uid inumber on /.mount/var: out of inodes which by itself is a clear indication. 2. The following log message can be observed: host []: … : No space left on device which is not deterministic and just a representation of a write error which could have several reasons. So the following check needs to be done: user@host> show system storage no-forwarding Filesystem Size Used Avail Capacity Mounted on /dev/ada1p1 475M 300M 137M 69% /.mount/var which indicates that the write error is not actually due to a lack of disk space. If either 1. or 2. has been confirmed, then the output of: user@host> file list /var/run/*.env | count need to be checked and if it indicates a high (>10000) number of files the system has been affected by this issue. This issue affects: Juniper Networks Junos OS All versions prior to 19.1R3-S8; 19.2 versions prior to 19.2R3-S6; 19.3 versions prior to 19.3R3-S5; 19.4 versions prior to 19.4R2-S6, 19.4R3-S7; 20.1 version 20.1R1 and later versions; 20.2 versions prior to 20.2R3-S5; 20.3 versions prior to 20.3R3-S4; 20.4 versions prior to 20.4R3; 21.1 versions prior to 21.1R3; 21.2 versions prior to 21.2R2. Juniper Networks Junos OS Evolved All versions prior to 20.4R3-EVO; 21.1 versions prior to 21.1R3-S1-EVO; 21.2 versions prior to 21.2R1-S1-EVO, 21.2R2-EVO.
