Philips e-Alert Unit (non-medical device), Version R2.1 and prior. The software transmits sensitive or security-critical data in cleartext in a communication channel that can be sniffed by unauthorized actors. The Philips e-Alert communication channel is not encrypted which could therefore lead to disclosure of personal contact information and application login credentials from within the same subnet.
CVE-2018-8841
In Advantech WebAccess versions V8.2_20170817 and prior, WebAccess versions V8.3.0 and prior, WebAccess Dashboard versions V.2.0.15 and prior, WebAccess Scada Node versions prior to 8.3.1, and WebAccess/NMS 2.0.3 and prior, an improper privilege management vulnerability may allow an authenticated user to modify files when read access should only be given to the user.
CVE-2018-8840
A remote attacker could send a carefully crafted packet in InduSoft Web Studio v8.1 and prior versions, and/or InTouch Machine Edition 2017 v8.1 and prior versions during a tag, alarm, or event related action such as read and write, which may allow remote code execution.
CVE-2018-8839
Delta PMSoft versions 2.10 and prior have multiple stack-based buffer overflow vulnerabilities where a .ppm file can introduce a value larger than is readable by PMSoft’s fixed-length stack buffer. This can cause the buffer to be overwritten, which may allow arbitrary code execution or cause the application to crash. CVSS v3 base score: 7.1; CVSS vector string: AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:H/A:H. Delta Electronics recommends affected users update to at least PMSoft v2.11, which was made available as of March 22, 2018, or the latest available version.
CVE-2018-8838
A weakness in access controls in CENTUM CS 1000 all versions, CENTUM CS 3000 versions R3.09.50 and earlier, CENTUM CS 3000 Small versions R3.09.50 and earlier, CENTUM VP versions R6.03.10 and earlier, CENTUM VP Small versions R6.03.10 and earlier, CENTUM VP Basic versions R6.03.10 and earlier, Exaopc versions R3.75.00 and earlier, B/M9000 CS all versions, and B/M9000 VP versions R8.01.01 and earlier may allow a local attacker to exploit the message management function of the system. A CVSS v3 base score of 6.5 has been calculated; the CVSS vector string is (AV:L/AC:H/PR:L/UI:N/S:U/C:L/I:H/A:H).
CVE-2018-8837
Processing specially crafted .pm3 files in Advantech WebAccess HMI Designer 2.1.7.32 and prior may cause the system to write outside the intended buffer area and may allow remote code execution.