CVE
Vendors
Products
Updated
CVSS v2
CVSS v3
In Johnson Controls Metasys System Versions 8.0 and prior and BCPro (BCM) all versions prior to 3.0.2, this vulnerability results from improper error handling in HTTP-based communications with the server, which could allow an attacker to obtain technical information.
Asda_soft, Cncsoft, Cncsoft-b, Cncsoft_screeneditor, Cnssoft_screeneditor, Commgr, Dcisoft, Delta_industrial_automation_dopsoft, Delta_industrial_automation_pmsoft, Delta_industrial_automation_screen_editor
2019-10-09
N/A
9.8 CRITICAL
Delta Electronics Delta Industrial Automation DOPSoft version 4.00.04 and prior performs read operations on a memory buffer where the position can be determined by a value read from a .dpa file. This may cause improper restriction of operations within the bounds of the memory buffer, allow remote code execution, alter the intended control flow, allow reading of sensitive information, or cause the application to crash.
A vulnerability was discovered in all versions of Medtronic MyCareLink 24950 and 24952 Patient Monitor. The affected products use per-product credentials that are stored in a recoverable format. An attacker can use these credentials for network authentication and encryption of local data at rest.
Asda_soft, Cncsoft, Cncsoft-b, Cncsoft_screeneditor, Cnssoft_screeneditor, Commgr, Dcisoft, Delta_industrial_automation_dopsoft, Delta_industrial_automation_pmsoft, Delta_industrial_automation_screen_editor
2019-10-09
N/A
9.8 CRITICAL
Delta Electronics Delta Industrial Automation DOPSoft version 4.00.04 and prior utilizes a fixed-length stack buffer where a value larger than the buffer can be read from a .dpa file into the buffer, causing the buffer to be overwritten. This may allow remote code execution or cause the application to crash.
AVEVA InduSoft Web Studio v8.1 and v8.1SP1, and InTouch Machine Edition v2017 8.1 and v2017 8.1 SP1 a remote user could send a carefully crafted packet to exploit a stack-based buffer overflow vulnerability during tag, alarm, or event related actions such as read and write, with potential for code to be executed.
A vulnerability was discovered in oVirt 4.1.x before 4.1.9, where the combination of Enable Discard and Wipe After Delete flags for VM disks managed by oVirt, could cause a disk to be incompletely zeroed when removed from a VM. If the same storage blocks happen to be later allocated to a new disk attached to another VM, potentially sensitive data could be revealed to privileged users of that VM.
An unquoted search path or element in RSLinx Classic Versions 3.90.01 and prior and FactoryTalk Linx Gateway Versions 3.90.00 and prior may allow an authorized, but non-privileged local user to execute arbitrary code and allow a threat actor to escalate user privileges on the affected workstation.
Davolink DVW-3200N all version prior to Version 1.00.06. The device generates a weak password hash that is easily cracked, allowing a remote attacker to obtain the password for the device.
Asda_soft, Cncsoft, Cncsoft-b, Cncsoft_screeneditor, Cnssoft_screeneditor, Commgr, Dcisoft, Delta_industrial_automation_dopsoft, Delta_industrial_automation_pmsoft, Delta_industrial_automation_screen_editor
2019-10-09
N/A
9.8 CRITICAL
Delta Electronics Delta Industrial Automation DOPSoft version 4.00.04 and prior utilizes a fixed-length heap buffer where a value larger than the buffer can be read from a .dpa file into the buffer, causing the buffer to be overwritten. This may allow remote code execution or cause the application to crash.
ABB Panel Builder 800 all versions has an improper input validation vulnerability which may allow an attacker to insert and run arbitrary code on a computer where the affected product is used.