CVE
Vendors
Products
Updated
CVSS v2
CVSS v3
WECON LeviStudio Versions 1.8.29 and 1.8.44 have multiple heap-based buffer overflow vulnerabilities that can be exploited when the application processes specially crafted project files.
Martem TELEM GW6/GWM versions prior to 2.0.87-4018403-k4 may allow unprivileged users to modify/upload a new system configuration or take the full control over the RTU using default credentials to connect to the RTU.
SEL Compass version 3.0.5.1 and prior allows all users full access to the SEL Compass directory, which may allow modification or overwriting of files within the Compass installation folder, resulting in escalation of privilege and/or malicious code execution.
Martem TELEM GW6 and GWM devices with firmware 2018.04.18-linux_4-01-601cb47 and prior do not perform authentication of IEC-104 control commands, which may allow a rogue node a remote control of the industrial process.
WECON LeviStudio Versions 1.8.29 and 1.8.44 have multiple stack-based buffer overflow vulnerabilities that can be exploited when the application processes specially crafted project files.
IntelliVue Patient Monitors MP Series (including MP2/X2/MP30/MP50/MP70/NP90/MX700/800) Rev B-M, IntelliVue Patient Monitors MX (MX400-550) Rev J-M and (X3/MX100 for Rev M only), and Avalon Fetal/Maternal Monitors FM20/FM30/FM40/FM50 with software Revisions F.0, G.0 and J.3 have a vulnerability that exposes an "echo" service, in which an attacker-sent buffer to an attacker-chosen device address within the same subnet is copied to the stack with no boundary checks, hence resulting in stack overflow.
SEL AcSELerator Architect version 2.2.24.0 and prior allows unsanitized input to be passed to the XML parser, which may allow disclosure and retrieval of arbitrary data, arbitrary code execution (in certain situations on specific platforms), and denial of service attacks.
python before versions 2.7.15, 3.4.9, 3.5.6rc1, 3.6.5rc1 and 3.7.0 is vulnerable to catastrophic backtracking in pop3lib's apop() method. An attacker could use this flaw to cause denial of service.
IntelliVue Patient Monitors MP Series (including MP2/X2/MP30/MP50/MP70/NP90/MX700/800) Rev B-M, IntelliVue Patient Monitors MX (MX400-550) Rev J-M and (X3/MX100 for Rev M only), and Avalon Fetal/Maternal Monitors FM20/FM30/FM40/FM50 with software Revisions F.0, G.0 and J.3 have a vulnerability that allows an unauthenticated attacker to read memory from an attacker-chosen device address within the same subnet.
Asda_soft, Cncsoft, Cncsoft-b, Cncsoft_screeneditor, Cnssoft_screeneditor, Commgr, Dcisoft, Delta_industrial_automation_dopsoft, Delta_industrial_automation_pmsoft, Delta_industrial_automation_screen_editor
2019-10-09
N/A
8.1 HIGH
CNCSoft Version 1.00.83 and prior with ScreenEditor Version 1.00.54 has two out-of-bounds read vulnerabilities could cause the software to crash due to lacking user input validation for processing project files. Which may allow an attacker to gain remote code execution with administrator privileges if exploited.