CVE
Vendors
Products
Updated
CVSS v2
CVSS v3
Hirschmann_hios, Hirschmann_ees20, Hirschmann_ees25, Hirschmann_eesx20, Hirschmann_eesx30, Hirschmann_grs1020, Hirschmann_grs1030, Hirschmann_grs1042, Hirschmann_grs1120, Hirschmann_grs1130
2021-06-17
N/A
9.8 CRITICAL
A buffer overflow vulnerability was found in some devices of Hirschmann Automation and Control HiOS and HiSecOS. The vulnerability is due to improper parsing of URL arguments. An attacker could exploit this vulnerability by specially crafting HTTP requests to overflow an internal buffer. The following devices using HiOS Version 07.0.02 and lower are affected: RSP, RSPE, RSPS, RSPL, MSP, EES, EES, EESX, GRS, OS, RED. The following devices using HiSecOS Version 03.2.00 and lower are affected: EAGLE20/30.
In Moxa PT-7528 series firmware, Version 4.0 or lower, and PT-7828 series firmware, Version 3.9 or lower, an attacker can gain access to sensitive information from the web service without authorization.
A local privilege escalation vulnerability has been identified in the GE Digital CIMPLICITY HMI/SCADA product v10.0 and prior. If exploited, this vulnerability could allow an adversary to modify the system, leading to the arbitrary execution of code. This vulnerability is only exploitable if an attacker has access to an authenticated session. GE Digital CIMPLICITY v11.0, released January 2020, contains mitigation for this local privilege escalation vulnerability. GE Digital recommends all users upgrade to GE CIMPLICITY v11.0 or newer.
Edr-810_firmware, Edr-810, Iologik_2512_firmware, Iologik_2512, Iologik_2512-t_firmware, Iologik_2512-t, Iologik_2512-hspa_firmware, Iologik_2512-hspa, Iologik_2512-hspa-t_firmware, Iologik_2512-hspa-t
2020-03-26
N/A
9.8 CRITICAL
In Moxa EDS-G516E Series firmware, Version 5.2 or lower, weak password requirements may allow an attacker to gain access using brute force.
Compactlogix_5370_l1_firmware, Compactlogix_5370_l1, Compactlogix_5370_l2_firmware, Compactlogix_5370_l2, Compactlogix_5370_l3_firmware, Compactlogix_5370_l3, Armor_compact_guardlogix_5370_firmware, Armor_compact_guardlogix_5370, Compact_guardlogix_5370_firmware, Compact_guardlogix_5370
2020-03-20
N/A
9.8 CRITICAL
Rockwell Automation MicroLogix 1400 Controllers Series B v21.001 and prior, Series A, all versions, MicroLogix 1100 Controller, all versions, RSLogix 500 Software v12.001 and prior, The cryptographic key utilized to help protect the account password is hard coded into the RSLogix 500 binary file. An attacker could identify cryptographic keys and use it for further cryptographic attacks that could ultimately lead to a remote attacker gaining unauthorized access to the controller.
In Moxa PT-7528 series firmware, Version 4.0 or lower, and PT-7828 series firmware, Version 3.9 or lower, a buffer overflow in the web server allows remote attackers to cause a denial-of-service condition or execute arbitrary code.
Compactlogix_5370_l1_firmware, Compactlogix_5370_l1, Compactlogix_5370_l2_firmware, Compactlogix_5370_l2, Compactlogix_5370_l3_firmware, Compactlogix_5370_l3, Armor_compact_guardlogix_5370_firmware, Armor_compact_guardlogix_5370, Compact_guardlogix_5370_firmware, Compact_guardlogix_5370
2020-03-20
N/A
7.5 HIGH
Rockwell Automation MicroLogix 1400 Controllers Series B v21.001 and prior, Series A, all versions, MicroLogix 1100 Controller, all versions, RSLogix 500 Software v12.001 and prior, A remote, unauthenticated attacker can send a request from the RSLogix 500 software to the victim’s MicroLogix controller. The controller will then respond to the client with used password values to authenticate the user on the client-side. This method of authentication may allow an attacker to bypass authentication altogether, disclose sensitive information, or leak credentials.
In Moxa PT-7528 series firmware, Version 4.0 or lower, and PT-7828 series firmware, Version 3.9 or lower, the affected products use a weak cryptographic algorithm, which may allow confidential information to be disclosed.
In all versions of Omron PLC CJ Series, an attacker can send a series of specific data packets within a short period, causing a service error on the PLC Ethernet module, which in turn causes a PLC service denied result.
In Moxa PT-7528 series firmware, Version 4.0 or lower, and PT-7828 series firmware, Version 3.9 or lower, these devices use a hard-coded service code for access to the console.