Honeywell Notifier Web Server (NWS) Version 3.50 is vulnerable to a path traversal attack, which allows an attacker to bypass access to restricted directories. Honeywell has released a firmware update to address the problem.
Digi International ConnectPort LTS 32 MEI, Firmware Version 1.4.3 (82002228_K 08/09/2018), bios Version 1.2. Multiple cross-site scripting vulnerabilities exist that could allow an attacker to cause a denial-of-service condition.
In Notifier Web Server (NWS) Version 3.50 and earlier, the Honeywell Fire Web Server’s authentication may be bypassed by a capture-replay attack from a web browser.
In Emerson ValveLink v12.0.264 to v13.4.118, a vulnerability in the ValveLink software may allow a local, unprivileged, trusted insider to escalate privileges due to insecure configuration parameters.
A Heap-based Buffer Overflow was found in Emerson OpenEnterprise SCADA Server 2.83 (if Modbus or ROC Interfaces have been installed and are in use) and all versions of OpenEnterprise 3.1 through 3.3.3, where a specially crafted script could execute code on the OpenEnterprise Server.
It is possible to unmask credentials and other sensitive information on “unprotected” project files, which may allow an attacker to remotely access the C-More Touch Panels EA9 series: firmware versions prior to 6.53 and manipulate system configurations.
Honeywell INNCOM INNControl 3 allows workstation users to escalate application user privileges through the modification of local configuration files.
In Rockwell Automation all versions of FactoryTalk Diagnostics software, a subsystem of the FactoryTalk Services Platform, FactoryTalk Diagnostics exposes a .NET Remoting endpoint via RNADiagnosticsSrv.exe at TCPtcp/8082, which can insecurely deserialize untrusted data.
In ApexPro Telemetry Server Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 & prior, Clinical Information Center (CIC) Versions 4.X and 5.X, CARESCAPE Central Station (CSCS) Versions 1.X, the affected products utilize a weak encryption scheme for remote desktop control, which may allow an attacker to obtain remote code execution of devices on the network.
In ApexPro Telemetry Server Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 & prior, Clinical Information Center (CIC) Versions 4.X and 5.X, CARESCAPE Central Station (CSCS) Versions 1.X, B450 Version 2.X, B650 Version 1.X, B650 Version 2.X, B850 Version 1.X, B850 Version 2.X, a vulnerability in the software update mechanism allows an authenticated attacker to upload arbitrary files on the system through a crafted update package.