CVE-2019-6569
Scalance Xp-200 Firmware, Siemens
Logo!8_bm_firmware, Logo!8_bm, Cp1604_firmware, Cp1604, Cp1616_firmware, Cp1616, Dk_standard_ethernet_controller_firmware, Dk_standard_ethernet_controller, Ek-ertec_200_firmware, Ek-ertec_200
2022-07-12
N/A
9.1 CRITICAL
The monitor barrier of the affected products insufficiently blocks data from being forwarded over the mirror port into the mirrored network. An attacker could use this behavior to transmit malicious packets to systems in the mirrored network, possibly influencing their configuration and runtime behavior.
CVE-2019-6568
Cp1616 Firmware, Siemens
Logo!8_bm_firmware, Logo!8_bm, Cp1604_firmware, Cp1604, Cp1616_firmware, Cp1616, Dk_standard_ethernet_controller_firmware, Dk_standard_ethernet_controller, Ek-ertec_200_firmware, Ek-ertec_200
2023-01-10
N/A
7.5 HIGH
The webserver of the affected devices contains a vulnerability that may lead to a denial of service condition. An attacker may cause a denial of service situation which leads to a restart of the webserver of the affected device. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the device.
CVE-2019-6567
Scalance X-414-3e Firmware, Siemens
Logo!8_bm_firmware, Logo!8_bm, Cp1604_firmware, Cp1604, Cp1616_firmware, Cp1616, Dk_standard_ethernet_controller_firmware, Dk_standard_ethernet_controller, Ek-ertec_200_firmware, Ek-ertec_200
2021-02-09
N/A
5.5 MEDIUM
A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All Versions < V5.2.4), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions < V4.1.3), SCALANCE X-414-3E (All versions). The affected devices store passwords in a recoverable format. An attacker may extract and recover device passwords from the device configuration. Successful exploitation requires access to a device configuration backup and impacts confidentiality of the stored passwords.
CVE-2019-6566
2020-10-16
N/A
7.8 HIGH
GE Communicator, all versions prior to 4.0.517, allows a non-administrative user to replace the uninstaller with a malicious version, which could allow an attacker to gain administrator privileges to the system.
CVE-2019-6565
Eds-510a Firmware, Moxa
Edr-810_firmware, Edr-810, Iologik_2512_firmware, Iologik_2512, Iologik_2512-t_firmware, Iologik_2512-t, Iologik_2512-hspa_firmware, Iologik_2512-hspa, Iologik_2512-hspa-t_firmware, Iologik_2512-hspa-t
2022-11-30
N/A
6.1 MEDIUM
Moxa IKS and EDS fails to properly validate user input, giving unauthenticated and authenticated attackers the ability to perform XSS attacks, which may be used to send a malicious script.
CVE-2019-6564
2023-01-31
N/A
7.8 HIGH
GE Communicator, all versions prior to 4.0.517, allows a non-administrative user to place malicious files within the installer file directory, which may allow an attacker to gain administrative privileges on a system during installation or upgrade.
CVE-2019-6563
Eds-510a Firmware, Moxa
Edr-810_firmware, Edr-810, Iologik_2512_firmware, Iologik_2512, Iologik_2512-t_firmware, Iologik_2512-t, Iologik_2512-hspa_firmware, Iologik_2512-hspa, Iologik_2512-hspa-t_firmware, Iologik_2512-hspa-t
2020-10-05
N/A
9.8 CRITICAL
Moxa IKS and EDS generate a predictable cookie calculated with an MD5 hash, allowing an attacker to capture the administrator's password, which could lead to a full compromise of the device.
CVE-2019-6562
2022-11-30
N/A
5.4 MEDIUM
In Philips Tasy EMR, Tasy EMR Versions 3.02.1744 and prior, the software incorrectly neutralizes user-controllable input before it is placed in output that is used as a web page that is served to other users.
CVE-2019-6561
Eds-510a Firmware, Moxa
Edr-810_firmware, Edr-810, Iologik_2512_firmware, Iologik_2512, Iologik_2512-t_firmware, Iologik_2512-t, Iologik_2512-hspa_firmware, Iologik_2512-hspa, Iologik_2512-hspa-t_firmware, Iologik_2512-hspa-t
2022-11-30
N/A
8.8 HIGH
Cross-site request forgery has been identified in Moxa IKS and EDS, which may allow for the execution of unauthorized actions on the device.
CVE-2019-6560
2020-03-25
N/A
9.1 CRITICAL
In Auto-Maskin RP210E Versions 3.7 and prior, DCU210E Versions 3.7 and prior and Marine Observer Pro (Android App), the software contains a mechanism for users to recover or change their passwords without knowing the original password, but the mechanism is weak.