CVE
Vendors
Products
Updated
CVSS v2
CVSS v3
Edr-810_firmware, Edr-810, Iologik_2512_firmware, Iologik_2512, Iologik_2512-t_firmware, Iologik_2512-t, Iologik_2512-hspa_firmware, Iologik_2512-hspa, Iologik_2512-hspa-t_firmware, Iologik_2512-hspa-t
2022-11-30
N/A
6.5 MEDIUM
Moxa IKS and EDS allow remote authenticated users to cause a denial of service via a specially crafted packet, which may cause the switch to crash.
In Auto-Maskin RP210E Versions 3.7 and prior, DCU210E Versions 3.7 and prior and Marine Observer Pro (Android App), the software contains a mechanism for users to recover or change their passwords without knowing the original password, but the mechanism is weak.
Edr-810_firmware, Edr-810, Iologik_2512_firmware, Iologik_2512, Iologik_2512-t_firmware, Iologik_2512-t, Iologik_2512-hspa_firmware, Iologik_2512-hspa, Iologik_2512-hspa-t_firmware, Iologik_2512-hspa-t
2022-11-30
N/A
9.8 CRITICAL
Several buffer overflow vulnerabilities have been identified in Moxa IKS and EDS, which may allow remote code execution.
When processing project files, the application (Omron CX-Programmer v9.70 and prior and Common Components January 2019 and prior) fails to check if it is referencing freed memory. An attacker could use a specially crafted project file to exploit and execute code under the privileges of the application.
Cscape, 9.80 SP4 and prior. An improper input validation vulnerability may be exploited by processing specially crafted POC files. This may allow an attacker to read confidential information and remotely execute arbitrary code.
Advantech WebAccess/SCADA, Versions 8.3.5 and prior. An improper access control vulnerability may allow an attacker to cause a denial-of-service condition.
A vulnerability was found in Rockwell Automation RSLinx Classic versions 4.10.00 and prior. An input validation issue in a .dll file of RSLinx Classic where the data in a Forward Open service request is passed to a fixed size buffer, allowing an attacker to exploit a stack-based buffer overflow condition.
Advantech WebAccess/SCADA, Versions 8.3.5 and prior. Multiple command injection vulnerabilities, caused by a lack of proper validation of user-supplied data, may allow remote code execution.
Pangea Communications Internet FAX ATA all Versions 3.1.8 and prior allow an attacker to bypass user authentication using a specially crafted URL to cause the device to reboot, which may be used to cause a continual denial-of-service condition.
Advantech WebAccess/SCADA, Versions 8.3.5 and prior. Multiple stack-based buffer overflow vulnerabilities, caused by a lack of proper validation of the length of user-supplied data, may allow remote code execution.