CVE-2019-6539
2020-10-05
N/A
7.8 HIGH
Several heap-based buffer overflow vulnerabilities in WECON LeviStudioU version 1.8.56 and prior have been identified, which may allow arbitrary code execution. Mat Powell, Ziad Badawi, and Natnael Samson working with Trend Micro's Zero Day Initiative, reported these vulnerabilities to NCCIC.
CVE-2019-6538
Maximo Ii Crt-d And Lcd Firmware, Medtronic
Minimed_508_firmware, Minimed_508, Minimed_paradigm_511_firmware, Minimed_paradigm_511, Minimed_paradigm_512_firmware, Minimed_paradigm_512, Minimed_paradigm_712_firmware, Minimed_paradigm_712, Minimed_paradigm_712e_firmware, Minimed_paradigm_712e
2020-10-06
N/A
6.5 MEDIUM
The Conexus telemetry protocol utilized within Medtronic MyCareLink Monitor versions 24950 and 24952, CareLink Monitor version 2490C, CareLink 2090 Programmer, Amplia CRT-D, Claria CRT-D, Compia CRT-D, Concerto CRT-D, Concerto II CRT-D, Consulta CRT-D, Evera ICD, Maximo II CRT-D and ICD, Mirro ICD, Nayamed ND ICD, Primo ICD, Protecta ICD and CRT-D, Secura ICD, Virtuoso ICD, Virtuoso II ICD, Visia AF ICD, and Viva CRT-D does not implement authentication or authorization. An attacker with adjacent short-range access to an affected product, in situations where the product’s radio is turned on, can inject, replay, modify, and/or intercept data within the telemetry communication. This communication protocol provides the ability to read and write memory values to affected implanted cardiac devices; therefore, an attacker could exploit this communication protocol to change memory in the implanted cardiac device.
CVE-2019-6537
2020-10-05
N/A
7.8 HIGH
Multiple stack-based buffer overflow vulnerabilities in WECON LeviStudioU version 1.8.56 and prior may be exploited when parsing strings within project files. The process does not properly validate the length of user-supplied data prior to copying it to a fixed-length stack-based buffer. An attacker can leverage these vulnerabilities to execute code under the context of the current process. Mat Powell, Ziad Badawi, and Natnael Samson working with Trend Micro's Zero Day Initiative, reported these vulnerabilities to NCCIC.
CVE-2019-6536
2019-04-02
N/A
7.8 HIGH
Opening a specially crafted LCDS LAquis SCADA before 4.3.1.71 ELS file may result in a write past the end of an allocated buffer, which may allow an attacker to execute remote code in the context of the current process.
CVE-2019-6535
Mitsubishielectric, Q50udehcpu Firmware
Electric_fr_configurator2_firmware, Electric_fr_configurator2, Qj71e71-100_firmware, Qj71e71-100, Q03/04/06/13/26udvcpu_firmware, Q03/04/06/13/26udvcpu, Q04/06/13/26udpvcpu_firmware, Q04/06/13/26udpvcpu, Q03udecpu_firmware, Q03udecpu
2023-01-31
N/A
7.5 HIGH
Mitsubishi Electric Q03/04/06/13/26UDVCPU: serial number 20081 and prior, Q04/06/13/26UDPVCPU: serial number 20081 and prior, and Q03UDECPU, Q04/06/10/13/20/26/50/100UDEHCPU: serial number 20101 and prior. A remote attacker can send specific bytes over Port 5007 that will result in an Ethernet stack crash.
CVE-2019-6534
2023-01-31
N/A
7.8 HIGH
The uncontrolled search path element vulnerability in Gemalto Sentinel UltraPro Client Library ux32w.dll Versions 1.3.0, 1.3.1, and 1.3.2 enables an attacker to load and execute a malicious file.
CVE-2019-6533
Kunbus, Pr100088 Modbus Gateway Firmware
Pr100088_modbus_gateway_firmware, Pr100088_modbus_gateway
2023-01-31
N/A
9.1 CRITICAL
Registers used to store Modbus values can be read and written from the web interface without authentication in the PR100088 Modbus gateway versions prior to Release R02 (or Software Version 1.1.13166).
CVE-2019-6532
2020-10-06
N/A
7.8 HIGH
Panasonic FPWIN Pro version 7.3.0.0 and prior allows attacker-created project files to be loaded by an authenticated user triggering incompatible type errors because the resource does not have expected properties. This may lead to remote code execution.
CVE-2019-6531
Kunbus, Pr100088 Modbus Gateway Firmware
Pr100088_modbus_gateway_firmware, Pr100088_modbus_gateway
2021-06-22
N/A
8.1 HIGH
An attacker could retrieve passwords from a HTTP GET request from the Kunbus PR100088 Modbus gateway versions prior to Release R02 (or Software Version 1.1.13166) if the attacker is in an MITM position.
CVE-2019-6530
2020-10-16
N/A
7.8 HIGH
Panasonic FPWIN Pro version 7.3.0.0 and prior allows attacker-created project files to be loaded by an authenticated user causing heap-based buffer overflows, which may lead to remote code execution.