• Skip to primary navigation
  • Skip to main content
CVE Vulnerability

CVE Vulnerability

  • CVE’s
  • Products
  • Vendors
Home » CVE’s

CVE’s


CVE
Vendors
Products
Updated
CVSS v2
CVSS v3
CVE-2019-6529
Kunbus, Pr100088 Modbus Gateway Firmware
Pr100088_modbus_gateway_firmware, Pr100088_modbus_gateway
2020-01-12
N/A
4.9 MEDIUM
An attacker could specially craft an FTP request that could crash the PR100088 Modbus gateway versions prior to release R02 (or Software Version 1.1.13166).
CVE-2019-6528
Psigridconnect, Telecontrol Gateway Xs-mu Firmware
Telecontrol_gateway_xs-mu_firmware, Telecontrol_gateway_xs-mu, Telecontrol_gateway_vm_firmware, Telecontrol_gateway_vm, Telecontrol_gateway_3g_firmware, Telecontrol_gateway_3g, Smart_telecontrol_unit_tcg_firmware, Smart_telecontrol_unit_tcg, Iec104_security_proxy_firmware, Iec104_security_proxy
2020-10-19
N/A
8.8 HIGH
PSI GridConnect GmbH Telecontrol Gateway and Smart Telecontrol Unit family, IEC104 Security Proxy versions Telecontrol Gateway 3G Versions 4.2.21, 5.0.27, 5.1.19, 6.0.16 and prior, and Telecontrol Gateway XS-MU Versions 4.2.21, 5.0.27, 5.1.19, 6.0.16 and prior, and Telecontrol Gateway VM Versions 4.2.21, 5.0.27, 5.1.19, 6.0.16 and prior, and Smart Telecontrol Unit TCG Versions 5.0.27, 5.1.19, 6.0.16 and prior, and IEC104 Security Proxy Version 2.2.10 and prior The web application browser interprets input as active HTML, JavaScript, or VBScript, which could allow an attacker to execute arbitrary code.
CVE-2019-6527
Kunbus, Pr100088 Modbus Gateway Firmware
Pr100088_modbus_gateway_firmware, Pr100088_modbus_gateway
2023-01-31
N/A
9.8 CRITICAL
PR100088 Modbus gateway versions prior to Release R02 (or Software Version 1.1.13166) may allow an attacker to be able to change the password for an admin user who is currently or previously logged in, provided the device has not been restarted.
CVE-2019-6526
Eds-510a Firmware, Moxa
Edr-810_firmware, Edr-810, Iologik_2512_firmware, Iologik_2512, Iologik_2512-t_firmware, Iologik_2512-t, Iologik_2512-hspa_firmware, Iologik_2512-hspa, Iologik_2512-hspa-t_firmware, Iologik_2512-hspa-t
2021-11-03
N/A
9.8 CRITICAL
Moxa IKS-G6824A series Versions 4.5 and prior, EDS-405A series Version 3.8 and prior, EDS-408A series Version 3.8 and prior, and EDS-510A series Version 3.8 and prior use plaintext transmission of sensitive data, which may allow an attacker to capture sensitive data such as an administrative password.
CVE-2019-6525
2020-10-16
N/A
8.8 HIGH
AVEVA Wonderware System Platform 2017 Update 2 and prior uses an ArchestrA network user account for authentication of system processes and inter-node communications. A user with low privileges could make use of an API to obtain the credentials for this account.
CVE-2019-6524
Eds-510a Firmware, Moxa
Edr-810_firmware, Edr-810, Iologik_2512_firmware, Iologik_2512, Iologik_2512-t_firmware, Iologik_2512-t, Iologik_2512-hspa_firmware, Iologik_2512-hspa, Iologik_2512-hspa-t_firmware, Iologik_2512-hspa-t
2020-10-19
N/A
9.8 CRITICAL
Moxa IKS and EDS do not implement sufficient measures to prevent multiple failed authentication attempts, which may allow an attacker to discover passwords via brute force attack.
CVE-2019-6523
2019-02-06
N/A
9.8 CRITICAL
WebAccess/SCADA, Version 8.3. The software does not properly sanitize its inputs for SQL commands.
CVE-2019-6522
Eds-510a Firmware, Moxa
Edr-810_firmware, Edr-810, Iologik_2512_firmware, Iologik_2512, Iologik_2512-t_firmware, Iologik_2512-t, Iologik_2512-hspa_firmware, Iologik_2512-hspa, Iologik_2512-hspa-t_firmware, Iologik_2512-hspa-t
2022-11-30
N/A
9.1 CRITICAL
Moxa IKS and EDS fails to properly check array bounds which may allow an attacker to read device memory on arbitrary addresses, and may allow an attacker to retrieve sensitive data or cause device reboot.
CVE-2019-6521
2019-02-06
N/A
8.6 HIGH
WebAccess/SCADA, Version 8.3. Specially crafted requests could allow a possible authentication bypass that could allow an attacker to obtain and manipulate sensitive information.
CVE-2019-6520
Eds-510a Firmware, Moxa
Edr-810_firmware, Edr-810, Iologik_2512_firmware, Iologik_2512, Iologik_2512-t_firmware, Iologik_2512-t, Iologik_2512-hspa_firmware, Iologik_2512-hspa, Iologik_2512-hspa-t_firmware, Iologik_2512-hspa-t
2020-10-19
N/A
7.5 HIGH
Moxa IKS and EDS does not properly check authority on server side, which results in a read-only user being able to perform arbitrary configuration changes.
« Previous 1 … 5,321 5,322 5,323 5,324 5,325 … 11,258 Next »

Copyright CVE Vulnerabilities 2023
Data Sources:

  • NIST
  • MITRE
  • CVE Search
  • Open CVE