• Skip to primary navigation
  • Skip to main content
CVE Vulnerability

CVE Vulnerability

  • CVE’s
  • Products
  • Vendors

CWE-787

CVE-2021-21898

February 23, 2023 by

A code execution vulnerability exists in the dwgCompressor::decompress18() functionality of LibreCad libdxfrw 2.2.0-rc2-19-ge02f3580. A specially-crafted .dwg file can lead to an out-of-bounds write. An attacker can provide a malicious file to trigger this vulnerability.

CVE-2021-21899

February 23, 2023 by

A code execution vulnerability exists in the dwgCompressor::copyCompBytes21 functionality of LibreCad libdxfrw 2.2.0-rc2-19-ge02f3580. A specially-crafted .dwg file can lead to a heap buffer overflow. An attacker can provide a malicious file to trigger this vulnerability.

CVE-2021-21901

February 23, 2023 by

A stack-based buffer overflow vulnerability exists in the CMA check_udp_crc function of Garrett Metal Detectors’ iC Module CMA Version 5.0. A specially-crafted packet can lead to a stack-based buffer overflow during a call to memcpy. An attacker can send a malicious packet to trigger this vulnerability.

CVE-2021-21903

February 23, 2023 by

A stack-based buffer overflow vulnerability exists in the CMA check_udp_crc function of Garrett Metal Detectors’ iC Module CMA Version 5.0. A specially-crafted packet can lead to a stack-based buffer overflow during a call to strcpy. An attacker can send a malicious packet to trigger this vulnerability.

CVE-2021-21905

February 23, 2023 by

Stack-based buffer overflow vulnerability exists in how the CMA readfile function of Garrett Metal Detectors iC Module CMA Version 5.0 is used at various locations. The Garrett iC Module exposes an authenticated CLI over TCP port 6877. This interface is used by a secondary GUI client, called “CMA Connect”, to interact with the iC Module on behalf of the user. After a client successfully authenticates, they can send plaintext commands to manipulate the device.

CVE-2021-21906

February 23, 2023 by

Stack-based buffer overflow vulnerability exists in how the CMA readfile function of Garrett Metal Detectors iC Module CMA Version 5.0 is used at various locations. The Garrett iC Module exposes an authenticated CLI over TCP port 6877. This interface is used by a secondary GUI client, called “CMA Connect”, to interact with the iC Module on behalf of the user. Every time a user submits a password to the CLI password prompt, the buffer containing their input is passed as the password parameter to the checkPassword function.

  • « Go to Previous Page
  • Go to page 1
  • Interim pages omitted …
  • Go to page 823
  • Go to page 824
  • Go to page 825
  • Go to page 826
  • Go to page 827
  • Interim pages omitted …
  • Go to page 1186
  • Go to Next Page »

Copyright CVE Vulnerabilities 2023
Data Sources:

  • NIST
  • MITRE
  • CVE Search
  • Open CVE