• Skip to primary navigation
  • Skip to main content
CVE Vulnerability

CVE Vulnerability

  • CVE’s
  • Products
  • Vendors

CWE-862

CVE-2019-8445

February 26, 2023 by

Several worklog rest resources in Jira before version 7.13.7, and from version 8.0.0 before version 8.3.2 allow remote attackers to view worklog time information via a missing permissions check.

CVE-2019-7272

February 26, 2023 by

Optergy Proton/Enterprise devices allow Username Disclosure.

CVE-2019-6961

February 26, 2023 by

Incorrect access control in actionHandlerUtility.php in the RDK RDKB-20181217-1 WebUI module allows a logged in user to control DDNS, QoS, RIP, and other privileged configurations (intended only for the network operator) by sending an HTTP POST to the PHP backend, because the page filtering for non-superuser (in header.php) is done only for GET requests and not for direct AJAX calls.

CVE-2019-6790

February 26, 2023 by

An Incorrect Access Control (issue 2 of 3) issue was discovered in GitLab Community and Enterprise Edition 8.14 and later but before 11.5.8, 11.6.x before 11.6.6, and 11.7.x before 11.7.1. Guest users were able to view the list of a group’s merge requests.

CVE-2019-6580

February 26, 2023 by

A vulnerability has been identified in Siveillance VMS 2017 R2 (All versions < V11.2a), Siveillance VMS 2018 R1 (All versions < V12.1a), Siveillance VMS 2018 R2 (All versions < V12.2a), Siveillance VMS 2018 R3 (All versions < V12.3a), Siveillance VMS 2019 R1 (All versions < V13.1a). An attacker with network access to port 80/TCP could change device properties without authorization. No user interaction is required to exploit this security vulnerability. Successful exploitation compromises confidentiality, integrity and availability of the targeted system. At the time of advisory publication no public exploitation of this security vulnerability was known.

CVE-2019-6538

February 26, 2023 by

The Conexus telemetry protocol utilized within Medtronic MyCareLink Monitor versions 24950 and 24952, CareLink Monitor version 2490C, CareLink 2090 Programmer, Amplia CRT-D, Claria CRT-D, Compia CRT-D, Concerto CRT-D, Concerto II CRT-D, Consulta CRT-D, Evera ICD, Maximo II CRT-D and ICD, Mirro ICD, Nayamed ND ICD, Primo ICD, Protecta ICD and CRT-D, Secura ICD, Virtuoso ICD, Virtuoso II ICD, Visia AF ICD, and Viva CRT-D does not implement authentication or authorization. An attacker with adjacent short-range access to an affected product, in situations where the product’s radio is turned on, can inject, replay, modify, and/or intercept data within the telemetry communication. This communication protocol provides the ability to read and write memory values to affected implanted cardiac devices; therefore, an attacker could exploit this communication protocol to change memory in the implanted cardiac device.

  • « Go to Previous Page
  • Go to page 1
  • Interim pages omitted …
  • Go to page 60
  • Go to page 61
  • Go to page 62
  • Go to page 63
  • Go to page 64
  • Interim pages omitted …
  • Go to page 211
  • Go to Next Page »

Copyright CVE Vulnerabilities 2023
Data Sources:

  • NIST
  • MITRE
  • CVE Search
  • Open CVE