• Skip to primary navigation
  • Skip to main content
CVE Vulnerability

CVE Vulnerability

  • CVE’s
  • Products
  • Vendors

CVE-2018-5461

February 26, 2023 by

An Inadequate Encryption Strength issue was discovered in Belden Hirschmann RS, RSR, RSB, MACH100, MACH1000, MACH4000, MS, and OCTOPUS Classic Platform Switches. An inadequate encryption strength vulnerability in the web interface has been identified, which may allow an attacker to obtain sensitive information through a successful man-in-the-middle attack.

CVE-2018-5459

February 26, 2023 by

An Improper Authentication issue was discovered in WAGO PFC200 Series 3S CoDeSys Runtime versions 2.3.X and 2.4.X. An attacker can execute different unauthenticated remote operations because of the CoDeSys Runtime application, which is available via network by default on Port 2455. An attacker could execute some unauthenticated commands such as reading, writing, or deleting arbitrary files, or manipulate the PLC application during runtime by sending specially-crafted TCP packets to Port 2455.

CVE-2018-5458

February 26, 2023 by

Philips IntelliSpace Portal all versions of 8.0.x, and 7.0.x have a vulnerability using SSL legacy encryption that could allow an attacker to gain unauthorized access to resources and information.

CVE-2018-5457

February 26, 2023 by

A uncontrolled search path element issue was discovered in Vyaire Medical CareFusion Upgrade Utility used with Windows XP systems, Versions 2.0.2.2 and prior versions. A successful exploit of this vulnerability requires the local user to install a crafted DLL on the target machine. The application loads the DLL and gives the attacker access at the same privilege level as the application.

CVE-2018-5455

February 26, 2023 by

A Reliance on Cookies without Validation and Integrity Checking issue was discovered in Moxa OnCell G3100-HSPA Series version 1.4 Build 16062919 and prior. The application allows a cookie parameter to consist of only digits, allowing an attacker to perform a brute force attack bypassing authentication and gaining access to device functions.

CVE-2018-5454

February 26, 2023 by

Philips IntelliSpace Portal all versions of 8.0.x, and 7.0.x have a vulnerability where code debugging methods are enabled, which could allow an attacker to remotely execute arbitrary code during runtime.

  • « Go to Previous Page
  • Go to page 1
  • Interim pages omitted …
  • Go to page 2821
  • Go to page 2822
  • Go to page 2823
  • Go to page 2824
  • Go to page 2825
  • Interim pages omitted …
  • Go to page 18763
  • Go to Next Page »

Copyright CVE Vulnerabilities 2023
Data Sources:

  • NIST
  • MITRE
  • CVE Search
  • Open CVE