An Improper Handling of Length Parameter Inconsistency issue was discovered in Moxa OnCell G3100-HSPA Series version 1.4 Build 16062919 and prior. An attacker may be able to edit the element of an HTTP request, causing the device to become unavailable.
CVE-2018-5452
A Stack-based Buffer Overflow issue was discovered in Emerson Process Management ControlWave Micro Process Automation Controller: ControlWave Micro [ProConOS v.4.01.280] firmware: CWM v.05.78.00 and prior. A stack-based buffer overflow vulnerability caused by sending crafted packets on Port 20547 could force the PLC to change its state into halt mode.
CVE-2018-5451
In Philips Alice 6 System version R8.0.2 or prior, when an actor claims to have a given identity, the software does not prove or insufficiently proves that the claim is correct. This weakness can lead to the exposure of resources or functionality to unintended actors, possibly providing attackers with sensitive information or the ability to execute arbitrary code.
CVE-2018-5449
A NULL Pointer Dereference issue was discovered in Moxa OnCell G3100-HSPA Series version 1.4 Build 16062919 and prior. The application does not check for a NULL value, allowing for an attacker to perform a denial of service attack.
CVE-2018-5448
All versions of the Medtronic 2090 Carelink Programmer are affected by a directory traversal vulnerability where the product’s software deployment network could allow an attacker to read files on the system.
CVE-2018-5447
An Improper Input Validation issue was discovered in Nari PCS-9611 relay. An improper input validation vulnerability has been identified that affects a service within the software that may allow a remote attacker to arbitrarily read/access system resources and affect the availability of the system.